Contec ECG Holter System TLC5000 (12 Lead)
Contec ECG Holter System TLC5000 can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software
12-lead system international standard
Small volume with OLED screen and the resolution is 160*128.
This ecg system is applicable for use in medical institution and community.
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
DETAILS
Technical Specifications
- Number of channels: 12 channels;
- Power: 2 AA size batteries;
- Scale voltage: 1mV± 5%;
- Standard Sensitivity: 10mm/mV± 5%;
- Noise level: ≤ 30μ V;
- CMRR: ≥ 60dB;
- Time constant≥ 3.2s;
- Scan speed: 25mm/s± 5%;
- Least measure signal: 50 µ V p-p;
- Product safety type: Type B (Internally powered).
Recorder Features
- Capacity:-2 GB
- Sampling accuracy:- 12 Bit
- Interface:-USB 2.0
- Record Time:- 24 hours
Software Features
- Sync Analyis:-Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
- Templates:- There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. And multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
- Channel Selection:- Flexible analysis channel selection function, can choose any channel as the main analysis of the channel
- Pacemaker Analysis:- Powerful pacemaker analysis, on the AAI, VVI, DDD etc. All pacemaker analysis.
- Analysis of heard rate variability:- Analysis of heard rate variability with short-range 5 minutes and long-range 1 hour and 24 hours analysis of heart rate variability. One-stop printing operation, report printing process is convenient and quick
- Abnormal ST analyzation:- Advanced ST segment analysis and myocardial ischemia total load, can for the ST abnormal analysis according to the whole and event, make the doctor can comprehensive judgment myocardial ischemia.
- "HRT" analysis function:-"HRT" analysis can predict the risk of death in patients with myocardial infarction.
- T-Wave alternation:-"T Wave alternation" analysis is an important index to predict malignant arrhythmia and sudden cardiac death.
- Sleep breath pause syndrome analysis:- Unique "Sleep breath pause syndrome analysis" analysis can predict Sleep breath pause risk
Accessories
- 12-lead ECG lead wires (1 set)
- ECG electrode 1 bag(20 per bag)
- USB data line(1)
- Disk(1)
- Bag(1)
- User manual(1)
Physical Characteristic
- Dimension: 111mm(L) *60mm(W) * 25mm(H)
- Weight: About 105g(without battery)