Contec ECG Holter System TLC9803 (3 Channel system)

https://www.mycolmed.in/web/image/product.template/38261/image_1920?unique=3c4f867

TLC9803 Dynamic ECG Systems adapts 3 channel 3-lead system.

₹ 33,147.52 33147.520000000004 INR ₹ 33,147.52

₹ 29,596.00

Not Available For Sale

This combination does not exist.

Terms and Conditions
30-day money-back guarantee

Shipping: 2-3 Business Days

Tecnical specifications 

  • Number of channels: 3 channels
  • Power: 2 AA size batteries
  • Scale voltage: 1mV±5%
  • Standard Sensitivity: 10mm/mV±5%
  • Noise level:≤  30µV
  • CMRR: ≥ 60dB
  •  Time constant :-≥ 3.2s
  • Scan speed: 25mm/s±5%
  • Least measure signal: 50 µV p-p
  • Product safety type: Type B (Internally powered)

Recorder:

  • Capacity:-2 GB
  • Sampling accuracy:-12 Bit
  • Inference:- USB2.0
  • Record Time:-24 Hours

 Software

  • Sync Analyis:-The 3-lead synchro analysis, to find accurate, QRS search can be accurate and no distortion.
  • Templates:- There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. And multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
  • Channel Selection:- Flexible analysis channel selection function, can choose any channel as the main analysis of the channel
  • Pacemaker Analysis:- Powerful pacemaker analysis, on the AAI, VVI, DDD etc. All pacemaker analysis.
  • Analysis of heard rate variability:-Analysis of heard rate variability with short-range 5 minutes and long-range 1 hour and 24 hours analysis of heart rate variability. One-stop printing operation, report printing process is convenient and quick
  • Abnormal ST analyzation:-Advanced ST segment analysis and myocardial ischemia total load, can for the ST abnormal analysis according to the whole and event, make the doctor can comprehensive judgment myocardial ischemia.
  • "HRT" analysis function:-"HRT" analysis can predict the risk of death in patients with myocardial infarction.
  • T-Wave alternation:- "T Wave alternation" analysis is an important index to predict malignant arrhythmia and sudden cardiac death. 
  • Sleep breath pause syndrome analysis:- Unique "Sleep breath pause syndrome analysis" analysis can predict Sleep breath pause risk

Accessories

  • 3-lead ECG lead wires (1 set)
  • ECG electrode 1 bag(20 per bag)
  • USB data line(1)
  • Disk(1)
  • Bag(1)
  • User manual(1)
  • Softdog

Physical Characteristic

  • Dimension: 111mm(L) *60mm(W) * 25mm(H)
  • Weight: About 105g(without battery)